{"product_id":"1812-100-gpd-lateral-membrane","title":"1812 100 GPD Lateral Membrane","description":"\u003ch1 data-start=\"403\" data-end=\"461\"\u003e1812 100 GPD RO \u003ca href=\"https:\/\/puritech.co.za\/product-category\/ro-membrane-elements\/\"\u003eMembrane\u003c\/a\u003e – Lateral Filtration Element\u003c\/h1\u003e \u003cp data-start=\"408\" data-end=\"864\"\u003eThe \u003cstrong data-start=\"412\" data-end=\"440\"\u003e1812 100 GPD RO Membrane\u003c\/strong\u003e is a reliable lateral reverse-osmosis element for homes and small commercial systems. \u003cstrong data-start=\"527\" data-end=\"543\"\u003eAdditionally\u003c\/strong\u003e, this membrane efficiently purifies low-salinity water from municipal sources, boreholes, or tap water, producing up to 380 liters per day. Its lateral-flow design allows flexible installation in standard 1812 RO housings, \u003cstrong data-start=\"767\" data-end=\"804\"\u003eensuring consistent water quality\u003c\/strong\u003e for drinking, cooking, and light commercial applications.\u003c\/p\u003e \u003ch3 data-start=\"871\" data-end=\"889\"\u003eKey Features\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"893\" data-end=\"930\"\u003e\n\u003cstrong data-start=\"893\" data-end=\"903\"\u003eModel:\u003c\/strong\u003e 1812 Lateral RO Membrane\u003c\/li\u003e \u003cli data-start=\"933\" data-end=\"973\"\u003e\n\u003cstrong data-start=\"933\" data-end=\"950\"\u003eRated Output:\u003c\/strong\u003e 100 GPD (~380 L\/day)\u003c\/li\u003e \u003cli data-start=\"976\" data-end=\"1027\"\u003e\n\u003cstrong data-start=\"976\" data-end=\"997\"\u003eIdeal Feed Water:\u003c\/strong\u003e Low-salinity (\u0026lt;500 ppm TDS)\u003c\/li\u003e \u003cli data-start=\"1030\" data-end=\"1087\"\u003e\n\u003cstrong data-start=\"1030\" data-end=\"1046\"\u003eFlow Design:\u003c\/strong\u003e Lateral feed for flexible installation\u003c\/li\u003e \u003cli data-start=\"1090\" data-end=\"1126\"\u003e\n\u003cstrong data-start=\"1090\" data-end=\"1109\"\u003eSalt Rejection:\u003c\/strong\u003e 93–97% typical\u003c\/li\u003e \u003cli data-start=\"1129\" data-end=\"1179\"\u003e\n\u003cstrong data-start=\"1129\" data-end=\"1152\"\u003eOperating Pressure:\u003c\/strong\u003e 50–125 psi (3.4–8.6 bar)\u003c\/li\u003e \u003cli data-start=\"1182\" data-end=\"1223\"\u003e\n\u003cstrong data-start=\"1182\" data-end=\"1203\"\u003eMaximum Pressure:\u003c\/strong\u003e 125 psi (8.6 bar)\u003c\/li\u003e \u003cli data-start=\"1226\" data-end=\"1272\"\u003e\n\u003cstrong data-start=\"1226\" data-end=\"1252\"\u003eOperating Temperature:\u003c\/strong\u003e 4–45°C (39–113°F)\u003c\/li\u003e \u003cli data-start=\"1275\" data-end=\"1314\"\u003e\n\u003cstrong data-start=\"1275\" data-end=\"1299\"\u003eMaximum Temperature:\u003c\/strong\u003e 45°C (113°F)\u003c\/li\u003e \u003cli data-start=\"1317\" data-end=\"1382\"\u003e\n\u003cstrong data-start=\"1317\" data-end=\"1340\"\u003eChlorine Tolerance:\u003c\/strong\u003e \u0026lt;0.1 ppm (requires dechlorinated water)\u003c\/li\u003e \u003cli data-start=\"1385\" data-end=\"1439\"\u003e\n\u003cstrong data-start=\"1385\" data-end=\"1411\"\u003eHousing Compatibility:\u003c\/strong\u003e Standard 1812 RO housings\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"1446\" data-end=\"1460\"\u003eBenefits\u003c\/h3\u003e \u003cp data-start=\"1462\" data-end=\"1793\"\u003eThis lateral RO membrane provides reliable water output with excellent dissolved solid removal. \u003cstrong data-start=\"1558\" data-end=\"1570\"\u003eMoreover\u003c\/strong\u003e, its lateral-flow design supports versatile plumbing layouts while ensuring long-lasting performance. The membrane is easy to install, maintain, and replace, \u003cstrong data-start=\"1729\" data-end=\"1790\"\u003eso households and small commercial setups benefit greatly\u003c\/strong\u003e.\u003c\/p\u003e \u003ch3 data-start=\"1800\" data-end=\"1832\"\u003eInstallation \u0026amp; Maintenance\u003c\/h3\u003e \u003col\u003e \u003cli data-start=\"1837\" data-end=\"1874\"\u003eConfirm 1812 housing compatibility.\u003c\/li\u003e \u003cli data-start=\"1878\" data-end=\"1965\"\u003e\n\u003cstrong data-start=\"1878\" data-end=\"1887\"\u003eFirst\u003c\/strong\u003e, pre-filter water with sediment and carbon filters to protect the membrane.\u003c\/li\u003e \u003cli data-start=\"1969\" data-end=\"2054\"\u003eInstall following the correct lateral flow direction and ensure O-rings are seated.\u003c\/li\u003e \u003cli data-start=\"2058\" data-end=\"2130\"\u003e\n\u003cstrong data-start=\"2058\" data-end=\"2066\"\u003eThen\u003c\/strong\u003e, flush the system after installation to remove preservatives.\u003c\/li\u003e \u003cli data-start=\"2134\" data-end=\"2193\"\u003eMonitor TDS and water flow; replace if performance drops.\u003c\/li\u003e \u003c\/ol\u003e \u003ch3 data-start=\"2200\" data-end=\"2218\"\u003eApplications\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"2222\" data-end=\"2250\"\u003eHome under-sink RO systems\u003c\/li\u003e \u003cli data-start=\"2253\" data-end=\"2285\"\u003eSmall commercial RO water bars\u003c\/li\u003e \u003cli data-start=\"2288\" data-end=\"2325\"\u003eLight industrial water purification\u003c\/li\u003e \u003c\/ul\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115699462213,"sku":"MEM100LAT","price":531.3,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/1812-100-GPD-Lateral-Membrane.jpg?v=1780903125","url":"https:\/\/www.monstermechanical.co.za\/products\/1812-100-gpd-lateral-membrane","provider":"Monster Mechanical","version":"1.0","type":"link"}