{"product_id":"1812-75-gpd-filmtec-ro-membrane","title":"1812 75 GPD Filmtec RO Membrane","description":"\u003ch1 data-start=\"719\" data-end=\"770\"\u003e\u003cstrong data-start=\"723\" data-end=\"770\"\u003eEssential Component for Domestic RO Systems\u003c\/strong\u003e\u003c\/h1\u003e \u003cp data-start=\"771\" data-end=\"1060\"\u003eThe \u003cstrong data-start=\"775\" data-end=\"803\"\u003e1812 RO membrane element\u003c\/strong\u003e is the primary purification stage in many domestic RO systems. It removes dissolved salts and other impurities from tap or well water, ensuring safe, clean drinking water. This element fits standard 1812 housings, making installation simple and reliable.\u003c\/p\u003e \u003ch3 data-start=\"1067\" data-end=\"1100\"\u003e\u003cstrong data-start=\"1071\" data-end=\"1100\"\u003eHow the RO Membrane Works\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"1101\" data-end=\"1398\"\u003eWater enters the membrane under pressure and passes through a thin‑film composite layer. Dissolved salts and other contaminants are left behind, while purified water continues to the storage tank. This process significantly reduces total dissolved solids (TDS), improving water taste and safety.\u003c\/p\u003e \u003ch3 data-start=\"1405\" data-end=\"1437\"\u003e\u003cstrong data-start=\"1409\" data-end=\"1437\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"TyagGW_tableContainer\"\u003e \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1438\" data-end=\"1840\"\u003e \u003cthead data-start=\"1438\" data-end=\"1472\"\u003e \u003ctr data-start=\"1438\" data-end=\"1472\"\u003e \u003cth data-start=\"1438\" data-end=\"1458\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1440\" data-end=\"1457\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e \u003cth data-start=\"1458\" data-end=\"1472\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1460\" data-end=\"1470\"\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"1507\" data-end=\"1840\"\u003e \u003ctr data-start=\"1507\" data-end=\"1552\"\u003e \u003ctd data-start=\"1507\" data-end=\"1523\" data-col-size=\"sm\"\u003eMembrane Type\u003c\/td\u003e \u003ctd data-start=\"1523\" data-end=\"1552\" data-col-size=\"sm\"\u003eThin‑Film Composite (TFC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1553\" data-end=\"1590\"\u003e \u003ctd data-start=\"1553\" data-end=\"1560\" data-col-size=\"sm\"\u003eSize\u003c\/td\u003e \u003ctd data-start=\"1560\" data-end=\"1590\" data-col-size=\"sm\"\u003e1.8″ × 12″ (1812 standard)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1591\" data-end=\"1628\"\u003e \u003ctd data-start=\"1591\" data-end=\"1605\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e \u003ctd data-start=\"1605\" data-end=\"1628\" data-col-size=\"sm\"\u003eDomestic RO systems\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1629\" data-end=\"1673\"\u003e \u003ctd data-start=\"1629\" data-end=\"1644\" data-col-size=\"sm\"\u003eFlow Ratings\u003c\/td\u003e \u003ctd data-start=\"1644\" data-end=\"1673\" data-col-size=\"sm\"\u003e75 GPD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1674\" data-end=\"1702\"\u003e \u003ctd data-start=\"1674\" data-end=\"1691\" data-col-size=\"sm\"\u003eSalt Rejection\u003c\/td\u003e \u003ctd data-start=\"1691\" data-end=\"1702\" data-col-size=\"sm\"\u003e96–98 %\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1703\" data-end=\"1734\"\u003e \u003ctd data-start=\"1703\" data-end=\"1723\" data-col-size=\"sm\"\u003eMax Feed Pressure\u003c\/td\u003e \u003ctd data-start=\"1723\" data-end=\"1734\" data-col-size=\"sm\"\u003e200 psi\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1735\" data-end=\"1763\"\u003e \u003ctd data-start=\"1735\" data-end=\"1752\" data-col-size=\"sm\"\u003eOperating Temp\u003c\/td\u003e \u003ctd data-start=\"1752\" data-end=\"1763\" data-col-size=\"sm\"\u003e2–45 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1764\" data-end=\"1783\"\u003e \u003ctd data-start=\"1764\" data-end=\"1775\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e \u003ctd data-start=\"1775\" data-end=\"1783\" data-col-size=\"sm\"\u003e2–11\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1784\" data-end=\"1801\"\u003e \u003ctd data-start=\"1784\" data-end=\"1794\" data-col-size=\"sm\"\u003eMax SDI\u003c\/td\u003e \u003ctd data-start=\"1794\" data-end=\"1801\" data-col-size=\"sm\"\u003e≤ 5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1802\" data-end=\"1840\"\u003e \u003ctd data-start=\"1802\" data-end=\"1828\" data-col-size=\"sm\"\u003eFree Chlorine Tolerance\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"1828\" data-end=\"1840\"\u003e\u0026lt;0.1 ppm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3 data-start=\"1847\" data-end=\"1884\"\u003e\u003cstrong data-start=\"1851\" data-end=\"1884\"\u003eBenefits of the 1812 Membrane\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"1887\" data-end=\"1943\"\u003eRemoves dissolved salts, heavy metals, and impurities.\u003c\/li\u003e \u003cli data-start=\"1946\" data-end=\"1997\"\u003eFits standard 1812 housings for easy replacement.\u003c\/li\u003e \u003cli data-start=\"2000\" data-end=\"2055\"\u003eWorks with tap, well, and low‑salinity water sources.\u003c\/li\u003e \u003cli data-start=\"2058\" data-end=\"2109\"\u003eProvides reliable, consistent water purification.\u003c\/li\u003e \u003cli data-start=\"2112\" data-end=\"2166\"\u003eLong service life when used with proper pre-filters.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2173\" data-end=\"2207\"\u003e\u003cstrong data-start=\"2177\" data-end=\"2207\"\u003eInstallation \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"2208\" data-end=\"2470\"\u003eTo install, turn off the water supply and relieve system pressure. Remove the old membrane and insert the new one, following the correct orientation. Flush the system before use. Regular pre-filter changes protect the membrane and maintain optimal performance.\u003c\/p\u003e","brand":"Filmtec","offers":[{"title":"1812 100 GPD Filmtec","offer_id":45115701919813,"sku":"MEM100F-2","price":736.38,"currency_code":"ZAR","in_stock":true},{"title":"1812 100 GPD Lateral Membrane","offer_id":45115701952581,"sku":"MEM100LAT-2","price":644.33,"currency_code":"ZAR","in_stock":true},{"title":"1812 100 GPD Superflow","offer_id":45115701985349,"sku":"MEM100S-2","price":184.09,"currency_code":"ZAR","in_stock":true},{"title":"1812 50 GPD Filmtec","offer_id":45115702018117,"sku":"MEM50F-2","price":644.32,"currency_code":"ZAR","in_stock":true},{"title":"1812 75 GPD Filmtec","offer_id":45115702050885,"sku":"MEM75F","price":552.28,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/1812-100-gpd-filmtec.webp?v=1780903170","url":"https:\/\/www.monstermechanical.co.za\/products\/1812-75-gpd-filmtec-ro-membrane","provider":"Monster Mechanical","version":"1.0","type":"link"}