{"product_id":"2000-gpd-ro-system","title":"2000 GPD RO System","description":"\u003ch2 data-start=\"620\" data-end=\"695\"\u003e2000 GPD RO System – High-Performance Industrial RO\u003c\/h2\u003e \u003cp data-start=\"697\" data-end=\"1069\"\u003eThe \u003cstrong data-start=\"701\" data-end=\"744\"\u003e2000 GPD RO System with Shimge PLD Pump\u003c\/strong\u003e delivers reliable, high-purity water for commercial and light-industrial applications. Designed for robustness and ease of maintenance, this system produces up to \u003cstrong data-start=\"908\" data-end=\"943\"\u003e2000 gallons per day (≈250 LPH)\u003c\/strong\u003e and integrates a powerful Shimge PLD vertical multistage pump to ensure stable feed pressure and consistent permeate quality.\u003c\/p\u003e \u003ch3 data-start=\"1071\" data-end=\"1087\"\u003eKey Features\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"1091\" data-end=\"1136\"\u003eHigh output: up to \u003cstrong data-start=\"1110\" data-end=\"1133\"\u003e2000 GPD (≈250 LPH)\u003c\/strong\u003e.\u003c\/li\u003e \u003cli data-start=\"1139\" data-end=\"1208\"\u003eShimge PLD vertical multistage pump for reliable pressure delivery.\u003c\/li\u003e \u003cli data-start=\"1211\" data-end=\"1269\"\u003eDual 20″ pre-filters (5 µm + 1 µm) to protect membranes.\u003c\/li\u003e \u003cli data-start=\"1272\" data-end=\"1338\"\u003eHigh salt rejection (up to ~99%) for drinking and process water.\u003c\/li\u003e \u003cli data-start=\"1341\" data-end=\"1406\"\u003eAdjustable recovery (≈45–50%) via concentrate regulation valve.\u003c\/li\u003e \u003cli data-start=\"1409\" data-end=\"1501\"\u003eStainless steel 304 skid, microcomputer control, flow meters and gauges for easy monitoring.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"1503\" data-end=\"1531\"\u003eTechnical Specifications\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"1535\" data-end=\"1569\"\u003e\n\u003cstrong data-start=\"1535\" data-end=\"1548\"\u003eCapacity:\u003c\/strong\u003e 2000 GPD \/ 250 LPH\u003c\/li\u003e \u003cli data-start=\"1572\" data-end=\"1619\"\u003e\n\u003cstrong data-start=\"1572\" data-end=\"1593\"\u003eWorking Pressure:\u003c\/strong\u003e 150–200 PSI (10–14 bar)\u003c\/li\u003e \u003cli data-start=\"1622\" data-end=\"1674\"\u003e\n\u003cstrong data-start=\"1622\" data-end=\"1635\"\u003eMembrane:\u003c\/strong\u003e 4040 × 1\u003c\/li\u003e \u003cli data-start=\"1677\" data-end=\"1726\"\u003e\n\u003cstrong data-start=\"1677\" data-end=\"1693\"\u003ePre-filters:\u003c\/strong\u003e 20″ housings × 2 (5 µm + 1 µm)\u003c\/li\u003e \u003cli data-start=\"1729\" data-end=\"1769\"\u003e\n\u003cstrong data-start=\"1729\" data-end=\"1747\"\u003eRecovery Rate:\u003c\/strong\u003e 45–50% (adjustable)\u003c\/li\u003e \u003cli data-start=\"1772\" data-end=\"1852\"\u003e\n\u003cstrong data-start=\"1772\" data-end=\"1794\"\u003eFeed Water Limits:\u003c\/strong\u003e Turbidity \u0026lt;5 SD, TDS \u0026lt;2000 ppm, pH 3–11, Iron \u0026lt;0.01 ppm\u003c\/li\u003e \u003cli data-start=\"1855\" data-end=\"1910\"\u003e\n\u003cstrong data-start=\"1855\" data-end=\"1870\"\u003eDimensions:\u003c\/strong\u003e ~65.5 × 55 × 131 cm\u003c\/li\u003e \u003cli data-start=\"1855\" data-end=\"1910\"\u003e\n\u003cstrong data-start=\"1893\" data-end=\"1904\"\u003eWeight:\u003c\/strong\u003e 64 kg\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"1912\" data-end=\"1962\"\u003eWater Analysis — Mandatory Before Installation\u003c\/h3\u003e \u003cp data-start=\"1964\" data-end=\"2572\"\u003eEvery installation of an \u003cstrong data-start=\"1989\" data-end=\"2013\"\u003eindustrial RO system\u003c\/strong\u003e, including this \u003cstrong data-start=\"2030\" data-end=\"2073\"\u003e2000 GPD RO System with Shimge PLD Pump\u003c\/strong\u003e, \u003cstrong data-start=\"2075\" data-end=\"2109\"\u003erequires a full water analysis\u003c\/strong\u003e before commissioning. Therefore, you must submit a lab report showing TDS, hardness, alkalinity, turbidity, iron, manganese, free chlorine, pH, and microbiological status. Based on the results, Puritech will recommend the correct pre-treatment (for example: sedimentation, multimedia filtration, softening, antiscalant dosing, or chlorination removal). Consequently, this process prevents premature membrane fouling, reduces downtime, and lowers lifecycle costs.\u003c\/p\u003e \u003ch3 data-start=\"2574\" data-end=\"2602\"\u003eApplications \u0026amp; Use Cases\u003c\/h3\u003e \u003cp data-start=\"2604\" data-end=\"2830\"\u003eThis system suits beverage bottling, laboratories, commercial kitchens, clinics, and industrial processes that need steady, high-quality water. Moreover, operators can scale capacity by adding parallel units for higher demand.\u003c\/p\u003e \u003ch3 data-start=\"2832\" data-end=\"2868\"\u003eInstallation \u0026amp; Maintenance Notes\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"2872\" data-end=\"2925\"\u003ePre-treat feed water as recommended after analysis.\u003c\/li\u003e \u003cli data-start=\"2928\" data-end=\"2982\"\u003eFlush membranes at startup and monitor permeate TDS.\u003c\/li\u003e \u003cli data-start=\"2985\" data-end=\"3053\"\u003eSchedule CIP and replace pre-filters when the pressure drop increases.\u003c\/li\u003e \u003cli data-start=\"3056\" data-end=\"3112\"\u003eUse supplied controls and gauges to detect issues early.\u003c\/li\u003e \u003c\/ul\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115697070149,"sku":"RO2000R","price":35880.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/IMG_6873psd.jpg?v=1780903089","url":"https:\/\/www.monstermechanical.co.za\/products\/2000-gpd-ro-system","provider":"Monster Mechanical","version":"1.0","type":"link"}