{"product_id":"2000-lph-ro-system","title":"2000 LPH RO System","description":"\u003ch1\u003e2000 LPH Reverse Osmosis System – Industrial Water Purification\u003c\/h1\u003e \u003cp data-start=\"923\" data-end=\"1255\"\u003eThe \u003cstrong data-start=\"927\" data-end=\"962\"\u003e2000 LPH reverse osmosis system\u003c\/strong\u003e is an industrial water purifier designed to remove dissolved salts, minerals, and other impurities from feed water. It produces up to \u003cstrong data-start=\"1097\" data-end=\"1129\"\u003e2 T\/H (2000 litres per hour)\u003c\/strong\u003e of clean water, making it suitable for \u003cstrong data-start=\"1169\" data-end=\"1252\"\u003eindustrial plants, bottling facilities, commercial operations, and laboratories\u003c\/strong\u003e.\u003c\/p\u003e \u003cp data-start=\"1257\" data-end=\"1555\"\u003eBecause this is a \u003cstrong data-start=\"1275\" data-end=\"1297\"\u003estandalone RO unit\u003c\/strong\u003e, it does \u003cstrong data-start=\"1307\" data-end=\"1345\"\u003enot include pretreatment equipment\u003c\/strong\u003e. Therefore, \u003cstrong data-start=\"1358\" data-end=\"1417\"\u003esediment filters, carbon filters, or antiscalant dosing\u003c\/strong\u003e should be installed upstream to protect the membranes. As a result, the system delivers \u003cstrong data-start=\"1506\" data-end=\"1535\"\u003econsistent, low-TDS water\u003c\/strong\u003e for industrial use.\u003c\/p\u003e \u003ch3 data-start=\"1562\" data-end=\"1581\"\u003e\u003cstrong data-start=\"1565\" data-end=\"1581\"\u003eHow It Works\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"1583\" data-end=\"1831\"\u003eFeed water first enters the system, and the \u003cstrong data-start=\"1627\" data-end=\"1649\"\u003ehigh-pressure pump\u003c\/strong\u003e drives it through semi-permeable \u003cstrong data-start=\"1683\" data-end=\"1699\"\u003eRO membranes\u003c\/strong\u003e. Consequently, salts and impurities are rejected to the wastewater side, while purified water passes through to the product line.\u003c\/p\u003e \u003cp data-start=\"1833\" data-end=\"2057\"\u003eMeanwhile, \u003cstrong data-start=\"1844\" data-end=\"1896\"\u003eflow meters, pressure gauges, and panel controls\u003c\/strong\u003e allow operators to monitor the system in real time. Therefore, the membranes remain protected, and the system runs efficiently even during continuous operation.\u003c\/p\u003e \u003ch3 data-start=\"2064\" data-end=\"2083\"\u003e\u003cstrong data-start=\"2067\" data-end=\"2083\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"2087\" data-end=\"2124\"\u003eHigh output of \u003cstrong data-start=\"2102\" data-end=\"2122\"\u003e2000 LPH (2 T\/H)\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli data-start=\"2127\" data-end=\"2195\"\u003eIndustrial-grade RO membranes for strong salt and impurity removal\u003c\/li\u003e \u003cli data-start=\"2198\" data-end=\"2244\"\u003eDurable FRP and stainless steel construction\u003c\/li\u003e \u003cli data-start=\"2247\" data-end=\"2313\"\u003eBuilt-in \u003cstrong data-start=\"2256\" data-end=\"2291\"\u003eflow meters and pressure gauges\u003c\/strong\u003e for easy monitoring\u003c\/li\u003e \u003cli data-start=\"2316\" data-end=\"2377\"\u003eEfficient energy use with \u003cstrong data-start=\"2342\" data-end=\"2375\"\u003e5 kW system power consumption\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli data-start=\"2380\" data-end=\"2412\"\u003eEasy operation and maintenance\u003c\/li\u003e \u003cli data-start=\"2415\" data-end=\"2466\"\u003eIdeal for continuous industrial or commercial use\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2473\" data-end=\"2497\"\u003e\u003cstrong data-start=\"2476\" data-end=\"2497\"\u003eSystem Components\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"2499\" data-end=\"2531\"\u003eThe 2000 LPH RO system includes:\u003c\/p\u003e \u003col\u003e \u003cli data-start=\"2536\" data-end=\"2652\"\u003e\n\u003cstrong data-start=\"2536\" data-end=\"2559\"\u003eHigh-pressure pump:\u003c\/strong\u003e CDM4-12, 2.2 kW, 380 V \/ 50 Hz, flange type (Q = 4 m³\/h, H = 95 m, NPSH = 2, N = 2900 rpm)\u003c\/li\u003e \u003cli data-start=\"2656\" data-end=\"2696\"\u003e\n\u003cstrong data-start=\"2656\" data-end=\"2681\"\u003eFRP membrane housing:\u003c\/strong\u003e 4040 × 8 pcs\u003c\/li\u003e \u003cli data-start=\"2700\" data-end=\"2732\"\u003e\n\u003cstrong data-start=\"2700\" data-end=\"2717\"\u003eRO membranes:\u003c\/strong\u003e 4040 × 8 pcs\u003c\/li\u003e \u003cli data-start=\"2736\" data-end=\"2778\"\u003e\n\u003cstrong data-start=\"2736\" data-end=\"2770\"\u003e20″ jumbo blue filter housing:\u003c\/strong\u003e 2 pcs\u003c\/li\u003e \u003cli data-start=\"2782\" data-end=\"2831\"\u003e\n\u003cstrong data-start=\"2782\" data-end=\"2808\"\u003eBrass solenoid valves:\u003c\/strong\u003e inlet 1.2″, flush 1″\u003c\/li\u003e \u003cli data-start=\"2835\" data-end=\"2886\"\u003e\n\u003cstrong data-start=\"2835\" data-end=\"2858\"\u003eBrass globe valves:\u003c\/strong\u003e DN15 × 2 pcs, DN20 × 1 pc\u003c\/li\u003e \u003cli data-start=\"2890\" data-end=\"2919\"\u003e\n\u003cstrong data-start=\"2890\" data-end=\"2913\"\u003eCoated electric box\u003c\/strong\u003e × 1\u003c\/li\u003e \u003cli data-start=\"2923\" data-end=\"2978\"\u003e\n\u003cstrong data-start=\"2923\" data-end=\"2945\"\u003ePressure switches:\u003c\/strong\u003e -0.5~3 bars × 1, 5~30 bars × 1\u003c\/li\u003e \u003cli data-start=\"2982\" data-end=\"3011\"\u003e\n\u003cstrong data-start=\"2982\" data-end=\"3001\"\u003eUPVC pipes PN16\u003c\/strong\u003e × 1 lot\u003c\/li\u003e \u003cli data-start=\"3016\" data-end=\"3080\"\u003e\n\u003cstrong data-start=\"3016\" data-end=\"3032\"\u003eFlow meters:\u003c\/strong\u003e wastewater 1–10 GPM × 1, product 2–20 GPM × 1\u003c\/li\u003e \u003cli data-start=\"3085\" data-end=\"3141\"\u003e\n\u003cstrong data-start=\"3085\" data-end=\"3105\"\u003ePressure gauges:\u003c\/strong\u003e panel type 1 MPa × 1, 2.5 MPa × 2\u003c\/li\u003e \u003c\/ol\u003e \u003ch3 data-start=\"3148\" data-end=\"3175\"\u003e\u003cstrong data-start=\"3151\" data-end=\"3175\"\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"TyagGW_tableContainer\"\u003e \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3177\" data-end=\"3745\"\u003e \u003cthead data-start=\"3177\" data-end=\"3206\"\u003e \u003ctr data-start=\"3177\" data-end=\"3206\"\u003e \u003cth data-start=\"3177\" data-end=\"3189\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e \u003cth data-start=\"3189\" data-end=\"3206\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"3237\" data-end=\"3745\"\u003e \u003ctr data-start=\"3237\" data-end=\"3268\"\u003e \u003ctd data-start=\"3237\" data-end=\"3255\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3239\" data-end=\"3254\"\u003eModel – SKU\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"3255\" data-end=\"3268\" data-col-size=\"sm\"\u003eRO2000LPH\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3269\" data-end=\"3304\"\u003e \u003ctd data-start=\"3269\" data-end=\"3284\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3271\" data-end=\"3283\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3284\" data-end=\"3304\"\u003e2 T\/H (2000 LPH)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3305\" data-end=\"3332\"\u003e \u003ctd data-start=\"3305\" data-end=\"3322\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3307\" data-end=\"3321\"\u003ePower (kW)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3322\" data-end=\"3332\"\u003e2.2 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3333\" data-end=\"3364\"\u003e \u003ctd data-start=\"3333\" data-end=\"3354\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3335\" data-end=\"3353\"\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3354\" data-end=\"3364\"\u003e3 bars\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3365\" data-end=\"3401\"\u003e \u003ctd data-start=\"3365\" data-end=\"3388\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3367\" data-end=\"3387\"\u003eRunning Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3388\" data-end=\"3401\"\u003e8–10 bars\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3402\" data-end=\"3437\"\u003e \u003ctd data-start=\"3402\" data-end=\"3416\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3404\" data-end=\"3415\"\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3416\" data-end=\"3437\"\u003e380 V \/ 50 Hz, 3P\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3438\" data-end=\"3474\"\u003e \u003ctd data-start=\"3438\" data-end=\"3467\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3440\" data-end=\"3466\"\u003eMembrane Recovery Rate\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3467\" data-end=\"3474\"\u003e15%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3475\" data-end=\"3509\"\u003e \u003ctd data-start=\"3475\" data-end=\"3499\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3477\" data-end=\"3498\"\u003eDesalination Rate\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3499\" data-end=\"3509\"\u003e95–98%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3510\" data-end=\"3539\"\u003e \u003ctd data-start=\"3510\" data-end=\"3532\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3512\" data-end=\"3531\"\u003eSystem Recovery\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3532\" data-end=\"3539\"\u003e50%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3540\" data-end=\"3571\"\u003e \u003ctd data-start=\"3540\" data-end=\"3559\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3542\" data-end=\"3558\"\u003eMax Feed TDS\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3559\" data-end=\"3571\"\u003e2000 ppm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3572\" data-end=\"3602\"\u003e \u003ctd data-start=\"3572\" data-end=\"3593\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3574\" data-end=\"3592\"\u003eMax Input Temp\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3593\" data-end=\"3602\"\u003e30 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3603\" data-end=\"3633\"\u003e \u003ctd data-start=\"3603\" data-end=\"3625\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3605\" data-end=\"3624\"\u003eInlet Pipe Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3625\" data-end=\"3633\"\u003e1.2″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3634\" data-end=\"3670\"\u003e \u003ctd data-start=\"3634\" data-end=\"3664\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3636\" data-end=\"3663\"\u003eProduct Water Pipe Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3664\" data-end=\"3670\"\u003e1″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3671\" data-end=\"3705\"\u003e \u003ctd data-start=\"3671\" data-end=\"3699\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3673\" data-end=\"3698\"\u003eWaste Water Pipe Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3699\" data-end=\"3705\"\u003e1″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3706\" data-end=\"3745\"\u003e \u003ctd data-start=\"3706\" data-end=\"3737\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3708\" data-end=\"3736\"\u003eSystem Power Consumption\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3737\" data-end=\"3745\"\u003e5 kW\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3 data-start=\"3752\" data-end=\"3782\"\u003e\u003cstrong data-start=\"3755\" data-end=\"3782\"\u003eOperation \u0026amp; Performance\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"3784\" data-end=\"3986\"\u003eThis system operates under \u003cstrong data-start=\"3811\" data-end=\"3828\"\u003ehigh pressure\u003c\/strong\u003e, which forces water molecules through the RO membranes while rejecting salts and impurities. Therefore, the system consistently produces \u003cstrong data-start=\"3966\" data-end=\"3983\"\u003elow-TDS water\u003c\/strong\u003e.\u003c\/p\u003e \u003cp data-start=\"3988\" data-end=\"4184\"\u003eIn addition, the \u003cstrong data-start=\"4005\" data-end=\"4040\"\u003ebuilt-in monitoring instruments\u003c\/strong\u003e allow operators to track flow and pressure. As a result, membrane performance is maintained, and the system runs efficiently over long periods.\u003c\/p\u003e \u003ch3 data-start=\"4191\" data-end=\"4210\"\u003e\u003cstrong data-start=\"4194\" data-end=\"4210\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"4212\" data-end=\"4267\"\u003eThe \u003cstrong data-start=\"4216\" data-end=\"4251\"\u003e2000 LPH reverse osmosis system\u003c\/strong\u003e is ideal for:\u003c\/p\u003e \u003cul\u003e \u003cli data-start=\"4271\" data-end=\"4306\"\u003eIndustrial water treatment plants\u003c\/li\u003e \u003cli data-start=\"4309\" data-end=\"4346\"\u003eCommercial and factory water supply\u003c\/li\u003e \u003cli data-start=\"4349\" data-end=\"4383\"\u003eBeverage and bottling facilities\u003c\/li\u003e \u003cli data-start=\"4386\" data-end=\"4414\"\u003eFood processing operations\u003c\/li\u003e \u003cli data-start=\"4417\" data-end=\"4463\"\u003eLaboratories and pharmaceutical water supply\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"4465\" data-end=\"4576\"\u003eBecause of its \u003cstrong data-start=\"4480\" data-end=\"4511\"\u003ehigh output and reliability\u003c\/strong\u003e, it performs well in \u003cstrong data-start=\"4533\" data-end=\"4575\"\u003econtinuous-use industrial environments\u003c\/strong\u003e.\u003c\/p\u003e \u003ch3 data-start=\"4583\" data-end=\"4622\"\u003e\u003cstrong data-start=\"4586\" data-end=\"4622\"\u003eInstallation \u0026amp; Maintenance Notes\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"4626\" data-end=\"4709\"\u003eConduct a \u003cstrong data-start=\"4636\" data-end=\"4654\"\u003ewater analysis\u003c\/strong\u003e before installation to determine pretreatment needs.\u003c\/li\u003e \u003cli data-start=\"4712\" data-end=\"4805\"\u003eInstall \u003cstrong data-start=\"4720\" data-end=\"4772\"\u003esediment, carbon filters, and antiscalant dosing\u003c\/strong\u003e upstream to protect membranes.\u003c\/li\u003e \u003cli data-start=\"4808\" data-end=\"4877\"\u003eQualified technicians should handle installation and commissioning.\u003c\/li\u003e \u003cli data-start=\"4880\" data-end=\"4952\"\u003eRegularly monitor \u003cstrong data-start=\"4898\" data-end=\"4925\"\u003eflow, pressure, and TDS\u003c\/strong\u003e to maintain performance.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"4959\" data-end=\"4988\"\u003e\u003cstrong data-start=\"4962\" data-end=\"4988\"\u003eWhy Choose This System\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"4990\" data-end=\"5290\"\u003eThe \u003cstrong data-start=\"4994\" data-end=\"5029\"\u003e2000 LPH reverse osmosis system\u003c\/strong\u003e combines \u003cstrong data-start=\"5039\" data-end=\"5110\"\u003eindustrial strength, consistent low-TDS output, and easy monitoring\u003c\/strong\u003e. Although it is a standalone RO unit, it works efficiently with pretreatment systems and provides reliable water purification for demanding industrial and commercial applications.\u003c\/p\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115694284869,"sku":"RO2000LPH","price":129030.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/2000-lph-industrial-ro-system.jpg?v=1780903027","url":"https:\/\/www.monstermechanical.co.za\/products\/2000-lph-ro-system","provider":"Monster Mechanical","version":"1.0","type":"link"}