{"product_id":"3000-lph-ro-system","title":"3000 LPH RO System","description":"\u003ch1 data-start=\"932\" data-end=\"1271\"\u003e3000 LPH Reverse Osmosis System – Industrial Water Purification\u003c\/h1\u003e \u003cp data-start=\"997\" data-end=\"1310\"\u003eThe \u003cstrong data-start=\"1001\" data-end=\"1036\"\u003e3000 LPH reverse osmosis system\u003c\/strong\u003e is a \u003cstrong data-start=\"1042\" data-end=\"1085\"\u003ehigh-capacity industrial water purifier\u003c\/strong\u003e designed to remove salts, minerals, and impurities from feed water. It produces up to \u003cstrong data-start=\"1172\" data-end=\"1199\"\u003e3 T\/H of purified water\u003c\/strong\u003e, making it suitable for \u003cstrong data-start=\"1224\" data-end=\"1307\"\u003eindustrial plants, beverage production, laboratories, and commercial operations\u003c\/strong\u003e.\u003c\/p\u003e \u003cp data-start=\"1312\" data-end=\"1590\"\u003eBecause this is a \u003cstrong data-start=\"1330\" data-end=\"1352\"\u003estandalone RO unit\u003c\/strong\u003e, it does \u003cstrong data-start=\"1362\" data-end=\"1400\"\u003enot include pretreatment equipment\u003c\/strong\u003e. Therefore, \u003cstrong data-start=\"1413\" data-end=\"1444\"\u003esediment and carbon filters\u003c\/strong\u003e or antiscalant dosing should be installed upstream to protect the membranes. As a result, the system delivers \u003cstrong data-start=\"1555\" data-end=\"1580\"\u003estable, low-TDS water\u003c\/strong\u003e reliably.\u003c\/p\u003e \u003ch3 data-start=\"1597\" data-end=\"1616\"\u003e\u003cstrong data-start=\"1600\" data-end=\"1616\"\u003eHow It Works\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"1618\" data-end=\"1840\"\u003eFeed water first enters the system and is pushed by the \u003cstrong data-start=\"1674\" data-end=\"1696\"\u003ehigh-pressure pump\u003c\/strong\u003e through \u003cstrong data-start=\"1705\" data-end=\"1721\"\u003eRO membranes\u003c\/strong\u003e. Consequently, salts and impurities remain on the reject side, while purified water passes through as product water.\u003c\/p\u003e \u003cp data-start=\"1842\" data-end=\"2058\"\u003eMeanwhile, \u003cstrong data-start=\"1853\" data-end=\"1905\"\u003eflow meters, pressure gauges, and panel controls\u003c\/strong\u003e allow operators to monitor system performance. Therefore, the membranes are protected, and the system runs efficiently even during continuous operation.\u003c\/p\u003e \u003ch3 data-start=\"2065\" data-end=\"2084\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2084\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"2088\" data-end=\"2125\"\u003eHigh output of \u003cstrong data-start=\"2103\" data-end=\"2123\"\u003e3000 LPH (3 T\/H)\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli data-start=\"2128\" data-end=\"2170\"\u003eIndustrial-grade \u003cstrong data-start=\"2145\" data-end=\"2168\"\u003emembranes and pumps\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli data-start=\"2173\" data-end=\"2219\"\u003eStrong removal of salts and dissolved solids\u003c\/li\u003e \u003cli data-start=\"2222\" data-end=\"2281\"\u003eEasy operation and monitoring with gauges and flow meters\u003c\/li\u003e \u003cli data-start=\"2284\" data-end=\"2330\"\u003eDurable stainless steel and brass components\u003c\/li\u003e \u003cli data-start=\"2333\" data-end=\"2382\"\u003eEfficient energy use with \u003cstrong data-start=\"2359\" data-end=\"2380\"\u003e7 kW system power\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli data-start=\"2385\" data-end=\"2435\"\u003eIdeal for industrial and commercial applications\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2442\" data-end=\"2466\"\u003e\u003cstrong data-start=\"2445\" data-end=\"2466\"\u003eSystem Components\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"2468\" data-end=\"2515\"\u003eThe system includes the following components:\u003c\/p\u003e \u003col\u003e \u003cli data-start=\"2520\" data-end=\"2602\"\u003e\n\u003cstrong data-start=\"2520\" data-end=\"2543\"\u003eHigh-pressure pump:\u003c\/strong\u003e CDL4-16, 380 V \/ 50 Hz, 3P (Q = 5 m³\/h, H = 132 m, 4 kW)\u003c\/li\u003e \u003cli data-start=\"2606\" data-end=\"2670\"\u003e\n\u003cstrong data-start=\"2606\" data-end=\"2625\"\u003eRaw water pump:\u003c\/strong\u003e EHM8-3 (Q = 5 m³\/h, H = 47 m, 1.85 kW, 3P)\u003c\/li\u003e \u003cli data-start=\"2674\" data-end=\"2723\"\u003e\n\u003cstrong data-start=\"2674\" data-end=\"2699\"\u003eFRP membrane housing:\u003c\/strong\u003e 8040 × 3 pcs, 300 PSI\u003c\/li\u003e \u003cli data-start=\"2727\" data-end=\"2759\"\u003e\n\u003cstrong data-start=\"2727\" data-end=\"2744\"\u003eRO membranes:\u003c\/strong\u003e 8040 × 3 pcs\u003c\/li\u003e \u003cli data-start=\"2763\" data-end=\"2817\"\u003e\n\u003cstrong data-start=\"2763\" data-end=\"2798\"\u003eSS304 precision filter housing:\u003c\/strong\u003e 30″ × 7 elements\u003c\/li\u003e \u003cli data-start=\"2821\" data-end=\"2870\"\u003e\n\u003cstrong data-start=\"2821\" data-end=\"2847\"\u003eBrass solenoid valves:\u003c\/strong\u003e inlet 1.5″, flush 1″\u003c\/li\u003e \u003cli data-start=\"2874\" data-end=\"2926\"\u003e\n\u003cstrong data-start=\"2874\" data-end=\"2897\"\u003eBrass globe valves:\u003c\/strong\u003e DN15 × 2 pcs, DN25 × 1 pcs\u003c\/li\u003e \u003cli data-start=\"2930\" data-end=\"2959\"\u003e\n\u003cstrong data-start=\"2930\" data-end=\"2953\"\u003eCoated electric box\u003c\/strong\u003e × 1\u003c\/li\u003e \u003cli data-start=\"2963\" data-end=\"3016\"\u003e\n\u003cstrong data-start=\"2963\" data-end=\"2985\"\u003ePressure switches:\u003c\/strong\u003e -0.5~3 bar × 1, 5~30 bar × 1\u003c\/li\u003e \u003cli data-start=\"3021\" data-end=\"3050\"\u003e\n\u003cstrong data-start=\"3021\" data-end=\"3040\"\u003eUPVC pipes PN16\u003c\/strong\u003e × 1 lot\u003c\/li\u003e \u003cli data-start=\"3055\" data-end=\"3110\"\u003e\n\u003cstrong data-start=\"3055\" data-end=\"3071\"\u003eFlow meters:\u003c\/strong\u003e waste 20 GPM × 1, product 30 GPM × 1\u003c\/li\u003e \u003cli data-start=\"3115\" data-end=\"3192\"\u003e\n\u003cstrong data-start=\"3115\" data-end=\"3135\"\u003ePressure gauges:\u003c\/strong\u003e panel type 1 MPa × 1, 2.5 MPa × 2; tube type 1 MPa × 1\u003c\/li\u003e \u003c\/ol\u003e \u003ch3 data-start=\"3199\" data-end=\"3226\"\u003e\u003cstrong data-start=\"3202\" data-end=\"3226\"\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"TyagGW_tableContainer\"\u003e \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3228\" data-end=\"3723\"\u003e \u003cthead data-start=\"3228\" data-end=\"3257\"\u003e \u003ctr data-start=\"3228\" data-end=\"3257\"\u003e \u003cth data-start=\"3228\" data-end=\"3240\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e \u003cth data-start=\"3240\" data-end=\"3257\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"3288\" data-end=\"3723\"\u003e \u003ctr data-start=\"3288\" data-end=\"3309\"\u003e \u003ctd data-start=\"3288\" data-end=\"3300\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3290\" data-end=\"3299\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3300\" data-end=\"3309\"\u003eSA-3T\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3310\" data-end=\"3345\"\u003e \u003ctd data-start=\"3310\" data-end=\"3325\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3324\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3325\" data-end=\"3345\"\u003e3 T\/H (3000 LPH)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3346\" data-end=\"3366\"\u003e \u003ctd data-start=\"3346\" data-end=\"3358\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3348\" data-end=\"3357\"\u003ePower\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3358\" data-end=\"3366\"\u003e3 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3367\" data-end=\"3397\"\u003e \u003ctd data-start=\"3367\" data-end=\"3388\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3369\" data-end=\"3387\"\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"3388\" data-end=\"3397\" data-col-size=\"sm\"\u003e3 BAR\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3398\" data-end=\"3434\"\u003e \u003ctd data-start=\"3398\" data-end=\"3421\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3400\" data-end=\"3420\"\u003eRunning Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"3421\" data-end=\"3434\" data-col-size=\"sm\"\u003e10–15 BAR\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3435\" data-end=\"3470\"\u003e \u003ctd data-start=\"3435\" data-end=\"3449\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3437\" data-end=\"3448\"\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3449\" data-end=\"3470\"\u003e380 V \/ 50 Hz, 3P\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3471\" data-end=\"3513\"\u003e \u003ctd data-start=\"3471\" data-end=\"3500\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3473\" data-end=\"3499\"\u003eMembrane Recovery Rate\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3500\" data-end=\"3513\"\u003e15% \/ pcs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3514\" data-end=\"3548\"\u003e \u003ctd data-start=\"3514\" data-end=\"3538\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3516\" data-end=\"3537\"\u003eDesalination Rate\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3538\" data-end=\"3548\"\u003e95–98%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3549\" data-end=\"3578\"\u003e \u003ctd data-start=\"3549\" data-end=\"3571\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3551\" data-end=\"3570\"\u003eSystem Recovery\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3571\" data-end=\"3578\"\u003e50%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3579\" data-end=\"3609\"\u003e \u003ctd data-start=\"3579\" data-end=\"3601\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3581\" data-end=\"3600\"\u003eInlet Pipe Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3601\" data-end=\"3609\"\u003e1.5″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3610\" data-end=\"3648\"\u003e \u003ctd data-start=\"3610\" data-end=\"3640\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3612\" data-end=\"3639\"\u003eProduct Water Pipe Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3640\" data-end=\"3648\"\u003e1.2″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3649\" data-end=\"3683\"\u003e \u003ctd data-start=\"3649\" data-end=\"3677\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3651\" data-end=\"3676\"\u003eWaste Water Pipe Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3677\" data-end=\"3683\"\u003e1″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"3684\" data-end=\"3723\"\u003e \u003ctd data-start=\"3684\" data-end=\"3715\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3686\" data-end=\"3714\"\u003eSystem Power Consumption\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-col-size=\"sm\" data-start=\"3715\" data-end=\"3723\"\u003e7 kW\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3 data-start=\"3730\" data-end=\"3760\"\u003e\u003cstrong data-start=\"3733\" data-end=\"3760\"\u003eOperation \u0026amp; Performance\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"3762\" data-end=\"3959\"\u003eThe system operates under \u003cstrong data-start=\"3788\" data-end=\"3805\"\u003ehigh pressure\u003c\/strong\u003e, which allows water molecules to pass through membranes while salts and impurities are rejected. Therefore, \u003cstrong data-start=\"3914\" data-end=\"3931\"\u003elow-TDS water\u003c\/strong\u003e is consistently produced.\u003c\/p\u003e \u003cp data-start=\"3961\" data-end=\"4220\"\u003eIn addition, monitoring instruments provide real-time data on \u003cstrong data-start=\"4023\" data-end=\"4044\"\u003eflow and pressure\u003c\/strong\u003e, ensuring stable operation and protecting the membranes. Because proper pretreatment is required upstream, scaling and fouling are minimized, which prolongs the membrane life.\u003c\/p\u003e \u003ch3 data-start=\"4227\" data-end=\"4246\"\u003e\u003cstrong data-start=\"4230\" data-end=\"4246\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"4248\" data-end=\"4299\"\u003eThe 3000 LPH reverse osmosis system is ideal for:\u003c\/p\u003e \u003cul\u003e \u003cli data-start=\"4303\" data-end=\"4338\"\u003eIndustrial water treatment plants\u003c\/li\u003e \u003cli data-start=\"4341\" data-end=\"4375\"\u003eBeverage and bottling facilities\u003c\/li\u003e \u003cli data-start=\"4378\" data-end=\"4406\"\u003eFood processing operations\u003c\/li\u003e \u003cli data-start=\"4409\" data-end=\"4455\"\u003eLaboratories and pharmaceutical water supply\u003c\/li\u003e \u003cli data-start=\"4458\" data-end=\"4506\"\u003eCommercial water systems needing low-TDS water\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"4513\" data-end=\"4552\"\u003e\u003cstrong data-start=\"4516\" data-end=\"4552\"\u003eInstallation \u0026amp; Maintenance Notes\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"4556\" data-end=\"4647\"\u003eConduct a \u003cstrong data-start=\"4566\" data-end=\"4584\"\u003ewater analysis\u003c\/strong\u003e before installation to determine the necessary pretreatment.\u003c\/li\u003e \u003cli data-start=\"4650\" data-end=\"4722\"\u003eInstall \u003cstrong data-start=\"4658\" data-end=\"4710\"\u003esediment, carbon filters, and antiscalant dosing\u003c\/strong\u003e upstream.\u003c\/li\u003e \u003cli data-start=\"4725\" data-end=\"4794\"\u003eQualified technicians should handle installation and commissioning.\u003c\/li\u003e \u003cli data-start=\"4797\" data-end=\"4877\"\u003eMonitor \u003cstrong data-start=\"4805\" data-end=\"4832\"\u003eflow, pressure, and TDS\u003c\/strong\u003e regularly to maintain membrane efficiency.\u003c\/li\u003e \u003cli data-start=\"4880\" data-end=\"4948\"\u003eFlush membranes periodically according to water quality and usage.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"4955\" data-end=\"4984\"\u003e\u003cstrong data-start=\"4958\" data-end=\"4984\"\u003eWhy Choose This System\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"4986\" data-end=\"5294\"\u003eThe \u003cstrong data-start=\"4990\" data-end=\"5025\"\u003e3000 LPH reverse osmosis system\u003c\/strong\u003e offers \u003cstrong data-start=\"5033\" data-end=\"5098\"\u003eindustrial durability, high capacity, and membrane efficiency\u003c\/strong\u003e. Although it is a standalone RO unit, it integrates well with pretreatment systems. Therefore, it delivers \u003cstrong data-start=\"5206\" data-end=\"5240\"\u003econsistent, high-quality water\u003c\/strong\u003e for demanding commercial and industrial applications.\u003c\/p\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115694317637,"sku":"RO3000LPH","price":151800.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/3000LPD.jpg?v=1780903028","url":"https:\/\/www.monstermechanical.co.za\/products\/3000-lph-ro-system","provider":"Monster Mechanical","version":"1.0","type":"link"}