{"product_id":"3012-ro-membrane-housing","title":"3012 RO Membrane Housing","description":"\u003ch1 data-start=\"765\" data-end=\"814\"\u003e\u003cstrong data-start=\"769\" data-end=\"814\"\u003e3012 RO Housing – Durable Membrane Vessel\u003c\/strong\u003e\u003c\/h1\u003e \u003cp data-start=\"815\" data-end=\"1145\"\u003eThe \u003cstrong data-start=\"819\" data-end=\"838\"\u003e3012 RO housing\u003c\/strong\u003e is a strong, compact vessel that holds standard 3″ × 12″ RO membranes. This \u003cstrong data-start=\"915\" data-end=\"939\"\u003e3012 membrane vessel\u003c\/strong\u003e purifies water at the molecular level, removing dissolved salts, chemicals, and other impurities. It fits most 3012 RO elements, making it perfect for replacements, system upgrades, or new installations.\u003c\/p\u003e \u003ch3 data-start=\"1147\" data-end=\"1192\"\u003e\u003cstrong data-start=\"1151\" data-end=\"1192\"\u003eHow the 3012 RO Membrane Vessel Works\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"1193\" data-end=\"1521\"\u003eWater enters the \u003cstrong data-start=\"1210\" data-end=\"1229\"\u003e3012 RO housing\u003c\/strong\u003e through the inlet port and flows along the \u003cstrong data-start=\"1273\" data-end=\"1293\"\u003e3012 RO membrane\u003c\/strong\u003e. The membrane purifies water, producing clean permeate through the center port while wastewater exits the drain. With this process, the \u003cstrong data-start=\"1431\" data-end=\"1455\"\u003e3012 membrane vessel\u003c\/strong\u003e ensures reliable and consistent water quality for everyday use.\u003c\/p\u003e \u003ch3 data-start=\"1523\" data-end=\"1555\"\u003e\u003cstrong data-start=\"1527\" data-end=\"1555\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"TyagGW_tableContainer\"\u003e \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1556\" data-end=\"1917\"\u003e \u003cthead data-start=\"1556\" data-end=\"1582\"\u003e \u003ctr data-start=\"1556\" data-end=\"1582\"\u003e \u003cth data-start=\"1556\" data-end=\"1572\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e \u003cth data-start=\"1572\" data-end=\"1582\" data-col-size=\"sm\"\u003eDetail\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"1610\" data-end=\"1917\"\u003e \u003ctr data-start=\"1610\" data-end=\"1649\"\u003e \u003ctd data-start=\"1610\" data-end=\"1630\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1612\" data-end=\"1629\"\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1630\" data-end=\"1649\" data-col-size=\"sm\"\u003e3012 (3″ × 12″)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1650\" data-end=\"1703\"\u003e \u003ctd data-start=\"1650\" data-end=\"1673\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1652\" data-end=\"1672\"\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1673\" data-end=\"1703\" data-col-size=\"sm\"\u003eFood-grade durable plastic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1704\" data-end=\"1750\"\u003e \u003ctd data-start=\"1704\" data-end=\"1720\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1706\" data-end=\"1719\"\u003ePort Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1720\" data-end=\"1750\" data-col-size=\"sm\"\u003e1\/4″ threaded inlet\/outlet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1751\" data-end=\"1799\"\u003e \u003ctd data-start=\"1751\" data-end=\"1769\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1753\" data-end=\"1768\"\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1769\" data-end=\"1799\" data-col-size=\"sm\"\u003eNPT (National Pipe Thread)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1800\" data-end=\"1835\"\u003e \u003ctd data-start=\"1800\" data-end=\"1823\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1802\" data-end=\"1822\"\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1823\" data-end=\"1835\" data-col-size=\"sm\"\u003e~125 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1836\" data-end=\"1880\"\u003e \u003ctd data-start=\"1836\" data-end=\"1864\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1863\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1864\" data-end=\"1880\" data-col-size=\"sm\"\u003e4 °C – 38 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1881\" data-end=\"1917\"\u003e \u003ctd data-start=\"1881\" data-end=\"1893\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1883\" data-end=\"1892\"\u003eColor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"1893\" data-end=\"1917\" data-col-size=\"sm\"\u003eWhite plastic finish\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3 data-start=\"1919\" data-end=\"1958\"\u003e\u003cstrong data-start=\"1923\" data-end=\"1958\"\u003eBenefits of the 3012 RO Housing\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"1961\" data-end=\"2006\"\u003eCompatible with standard 3012 RO membranes.\u003c\/li\u003e \u003cli data-start=\"2009\" data-end=\"2045\"\u003eDurable plastic resists corrosion.\u003c\/li\u003e \u003cli data-start=\"2048\" data-end=\"2103\"\u003eThreaded ports provide secure, leak-free connections.\u003c\/li\u003e \u003cli data-start=\"2106\" data-end=\"2155\"\u003eThe compact design fits under sinks or in cabinets.\u003c\/li\u003e \u003cli data-start=\"2158\" data-end=\"2224\"\u003eEasy maintenance: check O-rings and replace membranes as needed.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2226\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2230\" data-end=\"2265\"\u003eInstallation \u0026amp; Maintenance Tips\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"2266\" data-end=\"2545\"\u003eTo install the \u003cstrong data-start=\"2281\" data-end=\"2300\"\u003e3012 RO housing\u003c\/strong\u003e, mount it on a stable frame and use thread tape on all connections. Inspect O-rings before inserting membranes to ensure a tight seal. Additionally, regular cleaning and timely membrane replacement will keep the system performing efficiently.\u003c\/p\u003e \u003ch3 data-start=\"2547\" data-end=\"2573\"\u003e\u003cstrong data-start=\"2551\" data-end=\"2573\"\u003eIdeal Applications\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"2574\" data-end=\"2809\"\u003eThe \u003cstrong data-start=\"2578\" data-end=\"2602\"\u003e3012 membrane vessel\u003c\/strong\u003e works well for residential under-sink RO systems, small offices, light commercial water purification, and laboratories. By using this vessel, you can ensure consistent purified water wherever it’s needed.\u003c\/p\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115702476869,"sku":"HOU3012","price":242.86,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/3012-Plastic-Housing-scaled-1.jpg?v=1780903176","url":"https:\/\/www.monstermechanical.co.za\/products\/3012-ro-membrane-housing","provider":"Monster Mechanical","version":"1.0","type":"link"}