{"product_id":"4000gpd-ro-system-eco","title":"4000GPD RO System (ECO)","description":"\u003ch2 data-start=\"352\" data-end=\"382\"\u003e4000 GPD \u003ca href=\"https:\/\/puritech.co.za\/product-category\/ro-industrial\/\"\u003eRO System\u003c\/a\u003e (Eco)\u003c\/h2\u003e \u003cp data-start=\"384\" data-end=\"764\"\u003eThe \u003cstrong data-start=\"388\" data-end=\"416\"\u003e4000 GPD RO System (Eco)\u003c\/strong\u003e is designed for businesses that need reliable, high-quality purified water every day. This system delivers consistent performance and efficiency, making it ideal for small- to medium-scale water bottling, manufacturing, and industrial use. \u003cstrong data-start=\"657\" data-end=\"669\"\u003eMoreover\u003c\/strong\u003e, it is built with durable materials that ensure long-term operation and reduced maintenance.\u003c\/p\u003e \u003cp data-start=\"766\" data-end=\"1025\"\u003e\u003cstrong data-start=\"766\" data-end=\"781\"\u003eIn addition\u003c\/strong\u003e, this RO system includes energy-efficient components that help lower running costs. The \u003cstrong data-start=\"870\" data-end=\"898\"\u003e4000 GPD RO System (Eco)\u003c\/strong\u003e removes dissolved salts, chlorine, and organic matter, resulting in clean and safe water suitable for multiple applications.\u003c\/p\u003e \u003ch3 data-start=\"1027\" data-end=\"1064\"\u003eWhy Water Analysis Is Essential\u003c\/h3\u003e \u003cp data-start=\"1066\" data-end=\"1398\"\u003eEvery \u003cstrong data-start=\"1072\" data-end=\"1096\"\u003eindustrial RO system\u003c\/strong\u003e, including this 4000 GPD model, requires a \u003cstrong data-start=\"1140\" data-end=\"1158\"\u003ewater analysis\u003c\/strong\u003e before installation. \u003cstrong data-start=\"1180\" data-end=\"1195\"\u003eAs a result\u003c\/strong\u003e, the report determines the ideal pre-treatment design, membrane selection, and configuration. \u003cstrong data-start=\"1290\" data-end=\"1303\"\u003eTherefore\u003c\/strong\u003e, it ensures the system performs efficiently, reduces maintenance, and extends membrane life.\u003c\/p\u003e \u003cp data-start=\"1400\" data-end=\"1594\"\u003e\u003cstrong data-start=\"1400\" data-end=\"1415\"\u003eFurthermore\u003c\/strong\u003e, Puritech bases all industrial RO designs on accurate lab results. This approach guarantees that each unit matches the specific feed-water conditions and customer requirements.\u003c\/p\u003e \u003ch3 data-start=\"1672\" data-end=\"1701\"\u003eTechnical Specifications\u003c\/h3\u003e \u003cdiv class=\"_tableContainer_1rjym_1\"\u003e \u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1703\" data-end=\"2309\"\u003e \u003cthead data-start=\"1703\" data-end=\"1740\"\u003e \u003ctr data-start=\"1703\" data-end=\"1740\"\u003e \u003cth data-start=\"1703\" data-end=\"1715\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e \u003cth data-start=\"1715\" data-end=\"1740\" data-col-size=\"md\"\u003eTypical Value \/ Range\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"1751\" data-end=\"2309\"\u003e \u003ctr data-start=\"1751\" data-end=\"1793\"\u003e \u003ctd data-start=\"1751\" data-end=\"1762\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e \u003ctd data-start=\"1762\" data-end=\"1793\" data-col-size=\"md\"\u003e~4000 GPD (Gallons per Day)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1794\" data-end=\"1853\"\u003e \u003ctd data-start=\"1794\" data-end=\"1817\" data-col-size=\"sm\"\u003eFeed Water TDS Limit\u003c\/td\u003e \u003ctd data-start=\"1817\" data-end=\"1853\" data-col-size=\"md\"\u003eUp to 1000 ppm (or as specified)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1854\" data-end=\"1908\"\u003e \u003ctd data-start=\"1854\" data-end=\"1875\" data-col-size=\"sm\"\u003eOperating Pressure\u003c\/td\u003e \u003ctd data-start=\"1875\" data-end=\"1908\" data-col-size=\"md\"\u003e8 – 12 bar (or as per design)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1909\" data-end=\"1947\"\u003e \u003ctd data-start=\"1909\" data-end=\"1925\" data-col-size=\"sm\"\u003eRecovery Rate\u003c\/td\u003e \u003ctd data-start=\"1925\" data-end=\"1947\" data-col-size=\"md\"\u003e~60–65% (Eco mode)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1948\" data-end=\"1990\"\u003e \u003ctd data-start=\"1948\" data-end=\"1963\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e \u003ctd data-start=\"1963\" data-end=\"1990\" data-col-size=\"md\"\u003e220–240 V, single phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"1991\" data-end=\"2059\"\u003e \u003ctd data-start=\"1991\" data-end=\"2003\" data-col-size=\"sm\"\u003eMembranes\u003c\/td\u003e \u003ctd data-start=\"2003\" data-end=\"2059\" data-col-size=\"md\"\u003e4040 or XL-4040 membranes (number depends on design)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2060\" data-end=\"2140\"\u003e \u003ctd data-start=\"2060\" data-end=\"2083\" data-col-size=\"sm\"\u003eFlow Meters \u0026amp; Gauges\u003c\/td\u003e \u003ctd data-start=\"2083\" data-end=\"2140\" data-col-size=\"md\"\u003ePermeate, concentrate, and feed pressure gauges installed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2141\" data-end=\"2204\"\u003e \u003ctd data-start=\"2141\" data-end=\"2156\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e \u003ctd data-start=\"2156\" data-end=\"2204\" data-col-size=\"md\"\u003eStainless steel or coated frame \u0026amp; RO housing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2205\" data-end=\"2265\"\u003e \u003ctd data-start=\"2205\" data-end=\"2227\" data-col-size=\"sm\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e \u003ctd data-start=\"2227\" data-end=\"2265\" data-col-size=\"md\"\u003e(Insert exact mm\/kg values here)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2266\" data-end=\"2309\"\u003e \u003ctd data-start=\"2266\" data-end=\"2292\" data-col-size=\"sm\"\u003eWater Temperature Range\u003c\/td\u003e \u003ctd data-start=\"2292\" data-end=\"2309\" data-col-size=\"md\"\u003e5 °C to 45 °C\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch2 data-start=\"1017\" data-end=\"1045\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e \u003cul\u003e \u003cli data-start=\"1049\" data-end=\"1172\"\u003e\n\u003cstrong data-start=\"1049\" data-end=\"1064\"\u003eHigh Output\u003c\/strong\u003e: Designed to deliver 4000 GPD under standard conditions, making it suitable for high-demand applications.\u003c\/li\u003e \u003cli data-start=\"1175\" data-end=\"1273\"\u003e\n\u003cstrong data-start=\"1175\" data-end=\"1202\"\u003eEnergy Efficient Design\u003c\/strong\u003e: Eco model optimized for lower power consumption and water recovery.\u003c\/li\u003e \u003cli data-start=\"1276\" data-end=\"1363\"\u003e\n\u003cstrong data-start=\"1276\" data-end=\"1308\"\u003eDurability \u0026amp; Low Maintenance\u003c\/strong\u003e: Built with quality components to minimize downtime.\u003c\/li\u003e \u003cli data-start=\"1366\" data-end=\"1487\"\u003e\n\u003cstrong data-start=\"1366\" data-end=\"1397\"\u003ePre-treatment Compatibility\u003c\/strong\u003e: Can integrate sediment, activated carbon, and antiscalant dosing to protect membranes.\u003c\/li\u003e \u003cli data-start=\"1490\" data-end=\"1570\"\u003e\n\u003cstrong data-start=\"1490\" data-end=\"1513\"\u003eScalable \u0026amp; Flexible\u003c\/strong\u003e: Suitable for modular expansion or parallel operation.\u003c\/li\u003e \u003cli data-start=\"1573\" data-end=\"1665\"\u003e\n\u003cstrong data-start=\"1573\" data-end=\"1599\"\u003eUser-Friendly Controls\u003c\/strong\u003e: Incorporates monitoring, alarms, and easy operational interface.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2769\" data-end=\"2811\"\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h3\u003e \u003col\u003e \u003cli data-start=\"2816\" data-end=\"2893\"\u003e\n\u003cstrong data-start=\"2816\" data-end=\"2836\"\u003eSite Preparation\u003c\/strong\u003e: Ensure stable floor and space for maintenance access.\u003c\/li\u003e \u003cli data-start=\"2897\" data-end=\"2991\"\u003e\n\u003cstrong data-start=\"2897\" data-end=\"2919\"\u003eFeed Water Quality\u003c\/strong\u003e: Water analysis recommended—check TDS, hardness, chlorine, turbidity.\u003c\/li\u003e \u003cli data-start=\"2995\" data-end=\"3086\"\u003e\n\u003cstrong data-start=\"2995\" data-end=\"3012\"\u003ePre-treatment\u003c\/strong\u003e: Use sediment, activated carbon, and antiscalants to protect membranes.\u003c\/li\u003e \u003cli data-start=\"3090\" data-end=\"3173\"\u003e\n\u003cstrong data-start=\"3090\" data-end=\"3115\"\u003eElectrical \u0026amp; Plumbing\u003c\/strong\u003e: Use proper gauge wiring, grounding, pressure fittings.\u003c\/li\u003e \u003cli data-start=\"3177\" data-end=\"3263\"\u003e\n\u003cstrong data-start=\"3177\" data-end=\"3205\"\u003eFlushing \u0026amp; Commissioning\u003c\/strong\u003e: Flush membranes well before use; monitor permeate TDS.\u003c\/li\u003e \u003cli data-start=\"3267\" data-end=\"3360\"\u003e\n\u003cstrong data-start=\"3267\" data-end=\"3282\"\u003eMaintenance\u003c\/strong\u003e: Periodic checks on pump, membranes, flow meters, and cleaning as required.\u003c\/li\u003e \u003c\/ol\u003e \u003cp data-start=\"3362\" data-end=\"3461\"\u003eAvoid long idle periods; if idle for a while, perform periodic flushing or preservation procedures.\u003c\/p\u003e \u003chr data-start=\"3463\" data-end=\"3466\"\u003e \u003ch2 data-start=\"3468\" data-end=\"3512\"\u003eWhy Choose the 4000 GPD RO System — Eco\u003c\/h2\u003e \u003cp data-start=\"3514\" data-end=\"3910\"\u003eThe \u003cstrong data-start=\"3518\" data-end=\"3540\"\u003e4000 GPD RO System\u003c\/strong\u003e (Eco) offers a robust solution for high-demand water purification without excessive operational costs. Its eco-mode design yields better water efficiency and energy use. \u003cstrong data-start=\"3711\" data-end=\"3727\"\u003eAdditionally\u003c\/strong\u003e, its modular nature allows expansion or redundancy. For commercial users needing reliable, bulk purification, this model strikes a balance between performance and cost-effectiveness.\u003c\/p\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115697758277,"sku":"RO4000ECO","price":41400.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/2000gpd-eco-industrial-ro-system.jpg?v=1780903096","url":"https:\/\/www.monstermechanical.co.za\/products\/4000gpd-ro-system-eco","provider":"Monster Mechanical","version":"1.0","type":"link"}