{"product_id":"uf-membrane-aqu-200","title":"UF Membrane AQU-200","description":"\u003ch1\u003eAQU-200 UF Membrane – Ultrafiltration Hollow Fiber Filter\u003c\/h1\u003e \u003cp data-start=\"779\" data-end=\"1215\"\u003eThe \u003cstrong data-start=\"783\" data-end=\"806\"\u003eAQU-200 UF Membrane\u003c\/strong\u003e is a \u003cstrong data-start=\"812\" data-end=\"851\"\u003ehollow fiber ultrafiltration filter\u003c\/strong\u003e used in water treatment systems where high clarity and microbial removal are important. It traps bacteria, suspended solids, and other particulates while allowing clean water to pass through its fine pores. This makes it suitable as a \u003cstrong data-start=\"1087\" data-end=\"1125\"\u003estandalone ultrafiltration element\u003c\/strong\u003e or as a \u003cstrong data-start=\"1134\" data-end=\"1174\"\u003epre-treatment before reverse osmosis\u003c\/strong\u003e.\u003c\/p\u003e \u003cp data-start=\"1217\" data-end=\"1412\"\u003eUnlike chemical methods, ultrafiltration relies on physical separation, which enhances water clarity without chemical residues and keeps operating costs low.\u003c\/p\u003e \u003ch3 data-start=\"1419\" data-end=\"1451\"\u003e\u003cstrong data-start=\"1422\" data-end=\"1451\"\u003eHow Ultrafiltration Works\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"1453\" data-end=\"1710\"\u003eIn an ultrafiltration setup, water flows through a bundle of hollow fibers. The UF hollow fibers have very fine pores that hold back larger particles and microbes. As a result, the permeate (filtered water) has much lower turbidity and fewer contaminants.\u003c\/p\u003e \u003cp data-start=\"1712\" data-end=\"1910\"\u003eBecause the process operates at relatively low pressure, it requires less energy than high-pressure membrane systems while still delivering reliable throughput.\u003c\/p\u003e \u003ch3 data-start=\"1917\" data-end=\"1956\"\u003e\u003cstrong data-start=\"1920\" data-end=\"1956\"\u003eKey Advantages of This UF Filter\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli data-start=\"1960\" data-end=\"2034\"\u003eEfficient removal of bacteria, suspended solids, and larger contaminants\u003c\/li\u003e \u003cli data-start=\"2037\" data-end=\"2093\"\u003eHollow fiber construction boosts membrane surface area\u003c\/li\u003e \u003cli data-start=\"2096\" data-end=\"2160\"\u003eSuitable for both domestic water systems and commercial setups\u003c\/li\u003e \u003cli data-start=\"2163\" data-end=\"2224\"\u003eIdeal for pre-treatment ahead of more advanced purification\u003c\/li\u003e \u003cli data-start=\"2227\" data-end=\"2269\"\u003eDurable UPVC housing and epoxy end seals\u003c\/li\u003e \u003cli data-start=\"2272\" data-end=\"2322\"\u003eConsistent performance with lower operating cost\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2329\" data-end=\"2360\"\u003e\u003cstrong data-start=\"2332\" data-end=\"2360\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cdiv class=\"TyagGW_tableContainer\"\u003e \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e \u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2362\" data-end=\"3055\"\u003e \u003cthead data-start=\"2362\" data-end=\"2389\"\u003e \u003ctr data-start=\"2362\" data-end=\"2389\"\u003e \u003cth data-start=\"2362\" data-end=\"2378\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e \u003cth data-start=\"2378\" data-end=\"2389\" data-col-size=\"sm\"\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody data-start=\"2418\" data-end=\"3055\"\u003e \u003ctr data-start=\"2418\" data-end=\"2458\"\u003e \u003ctd data-start=\"2418\" data-end=\"2429\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2420\" data-end=\"2428\"\u003eSize\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2429\" data-end=\"2458\" data-col-size=\"sm\"\u003eΦ200 × 1480 mm (standard)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2459\" data-end=\"2519\"\u003e \u003ctd data-start=\"2459\" data-end=\"2487\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2461\" data-end=\"2486\"\u003eHollow Fiber Material\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2487\" data-end=\"2519\" data-col-size=\"sm\"\u003ePAN \/ PS \/ PP \/ PVDF options\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2520\" data-end=\"2580\"\u003e \u003ctd data-start=\"2520\" data-end=\"2545\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2522\" data-end=\"2544\"\u003eHollow Fiber ID\/OD\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2545\" data-end=\"2580\" data-col-size=\"sm\"\u003e0.4–1.6 mm (varies by material)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2581\" data-end=\"2636\"\u003e \u003ctd data-start=\"2581\" data-end=\"2601\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2583\" data-end=\"2600\"\u003eMembrane Area\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2601\" data-end=\"2636\" data-col-size=\"sm\"\u003e25–48 m² (depending on variant)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2637\" data-end=\"2680\"\u003e \u003ctd data-start=\"2637\" data-end=\"2663\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2639\" data-end=\"2662\"\u003eDesigned Water Flux\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2663\" data-end=\"2680\" data-col-size=\"sm\"\u003e40–120 L\/m²\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2681\" data-end=\"2733\"\u003e \u003ctd data-start=\"2681\" data-end=\"2719\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2683\" data-end=\"2718\"\u003eInitial Flux (0.1 MPa at 25 °C)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2719\" data-end=\"2733\" data-col-size=\"sm\"\u003e\u0026gt; 6000 L\/h\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2734\" data-end=\"2770\"\u003e \u003ctd data-start=\"2734\" data-end=\"2758\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2736\" data-end=\"2757\"\u003eMax Feed Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2758\" data-end=\"2770\" data-col-size=\"sm\"\u003e~0.3 MPa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2771\" data-end=\"2812\"\u003e \u003ctd data-start=\"2771\" data-end=\"2794\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2773\" data-end=\"2793\"\u003eNormal TMP Range\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2794\" data-end=\"2812\" data-col-size=\"sm\"\u003e~0.02–0.15 MPa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2813\" data-end=\"2846\"\u003e \u003ctd data-start=\"2813\" data-end=\"2834\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2815\" data-end=\"2833\"\u003eFeed Turbidity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2834\" data-end=\"2846\" data-col-size=\"sm\"\u003e\u0026lt; 50 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2847\" data-end=\"2885\"\u003e \u003ctd data-start=\"2847\" data-end=\"2872\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2849\" data-end=\"2871\"\u003ePermeate Turbidity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2872\" data-end=\"2885\" data-col-size=\"sm\"\u003e\u0026lt; 0.1 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2886\" data-end=\"2918\"\u003e \u003ctd data-start=\"2886\" data-end=\"2907\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2888\" data-end=\"2906\"\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2907\" data-end=\"2918\" data-col-size=\"sm\"\u003e5–45 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2919\" data-end=\"2977\"\u003e \u003ctd data-start=\"2919\" data-end=\"2934\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2921\" data-end=\"2933\"\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"2934\" data-end=\"2977\" data-col-size=\"sm\"\u003eMaterial dependent (e.g., 1–14 PP type)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-start=\"2978\" data-end=\"3055\"\u003e \u003ctd data-start=\"2978\" data-end=\"3006\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2980\" data-end=\"3005\"\u003eMicroorganism Removal\u003c\/strong\u003e\u003c\/td\u003e \u003ctd data-start=\"3006\" data-end=\"3016\" data-col-size=\"sm\"\u003e~99.99%\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3 data-start=\"3062\" data-end=\"3094\"\u003e\u003cstrong data-start=\"3065\" data-end=\"3094\"\u003eWhere This Filter Is Used\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"3096\" data-end=\"3161\"\u003eThis type of hollow fiber ultrafiltration element fits well in:\u003c\/p\u003e \u003cul\u003e \u003cli data-start=\"3164\" data-end=\"3206\"\u003eHousehold and point-of-use water systems\u003c\/li\u003e \u003cli data-start=\"3209\" data-end=\"3271\"\u003ePre-RO treatment trains to protect reverse osmosis membranes\u003c\/li\u003e \u003cli data-start=\"3274\" data-end=\"3315\"\u003eSmall commercial water filtration units\u003c\/li\u003e \u003cli data-start=\"3318\" data-end=\"3365\"\u003eDrinking water clarifiers and booster systems\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"3367\" data-end=\"3486\"\u003eBecause it reduces turbidity and pathogenic load, this filter also helps downstream purification stages perform better.\u003c\/p\u003e \u003ch3 data-start=\"3493\" data-end=\"3526\"\u003e\u003cstrong data-start=\"3496\" data-end=\"3526\"\u003eInstallation and Care Tips\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"3528\" data-end=\"3806\"\u003eBefore installing the UF module, make sure your system has appropriate \u003cstrong data-start=\"3599\" data-end=\"3615\"\u003epretreatment\u003c\/strong\u003e to remove large solids that could foul the fibers. Once in place, periodic flushing or backwashing (depending on system design) helps extend service life and maintain consistent performance.\u003c\/p\u003e \u003ch3 data-start=\"3813\" data-end=\"3854\"\u003e\u003cstrong data-start=\"3816\" data-end=\"3854\"\u003eWhy Choose the AQU-200 UF Membrane\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"3856\" data-end=\"4156\"\u003eChoosing this hollow fiber ultrafiltration component gives you dependable physical filtration and improved water clarity with low energy needs. It’s particularly effective where microbial safety and particle removal are priorities, and it works well both alone or ahead of finer purification systems.\u003c\/p\u003e","brand":"Monster Mechanical","offers":[{"title":"Default","offer_id":45115694022725,"sku":"AQU-200","price":14254.02,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/8627\/7445\/files\/UF-Membrane-AQU-200-1.jpg?v=1780903021","url":"https:\/\/www.monstermechanical.co.za\/products\/uf-membrane-aqu-200","provider":"Monster Mechanical","version":"1.0","type":"link"}